Illustrated title card for the guide: Short-Depth 4U GPU Rackmount Cases for Home Racks (17–20 in)

Guide

Short-Depth 4U GPU Rackmount Cases for Home Racks (17–20 in)

Compare three 17- to 20-inch 4U GPU rackmount cases by depth and GPU length, then check rail reach, cabinet space, and power cable clearance.

Start with the 17-inch Sliger CX4170a if cabinet depth is tight. The 485 mm Inter-Tech 4U-47045 offers three external 5.25-inch bays and room for cards up to 330 mm. The 20-inch Sliger CX4200a has the highest published GPU length limit of the three. Sliger CX4170a · Inter-Tech 4U-47045 · Sliger CX4200a

Compare chassis depth and GPU room

4U casePublished case depthPublished GPU length limitCPU cooling supportPower supply options
Sliger CX4170a17 in375 mmAir cooler up to 153 mm or a 360 mm AIOATX, with redundant PSU options
Inter-Tech 4U-47045485 mm330 mmCPU cooler up to 145 mmATX or mini-redundant PS/2
Sliger CX4200a20 in450 mmAir cooler up to 153 mm or a 360 mm AIOATX, with redundant PSU options

Both Sliger models list eight PCIe slots and a maximum card height of 158 mm. Sliger CX4170a · Sliger CX4200a

Measure the rack and match the rails

  • Check the cabinet interior. Measure the open space behind the front mounting posts and compare it with the published case depth in the table.
  • Match the brackets to the rack. Check the front and rear mounting positions at the same height. For Sliger’s General Devices Rev B slides, the rear support brackets must reach the rear mounting holes of the slides. Use the instructions for the kit you plan to install. Sliger Rev B slide guide

Check the exact GPU and its cable

A 375 mm card reaches the CX4170a’s published length limit, comes in below the CX4200a’s limit and exceeds the Inter-Tech’s limit. Sliger CX4170a · Sliger CX4200a · Inter-Tech 4U-47045

For either Sliger, confirm the available GPU length with the intended front fans or radiator in place. Check the card’s height and how many slots it occupies. Sliger CX4170a · Sliger CX4200a

For a 12V-2×6 cable or adapter, check the space between the power plug and the panel with the cable routed. The panel should close without pinching the cable or shifting the connector. Seasonic cable-clearance guidance

Evidence and limits

The comparison follows GPU Chassis Guide’s published-specs policy. Manufacturer specifications and fit guidance, including Sliger’s Rev B rail instructions, were checked on November 27, 2026. No hands-on fit testing was performed. Site-wide affiliate disclosure

Related bays